Olyair O series wall mounted type split air conditioner

Place of Origin : China

Brand Name : OLYAIR

Certification : CE, ROHS

Model Number : OSR-24HRFN1

Use : Room

Power Source : Electrical

Type : Split Wall Mounted Air Conditioners

Cooling/Heating : Cooling/Heating

Capacity (btu) : 24000

COP : 4.0

EER : 3.5

Power (W) : 7000

Voltage (V) : 220

MOQ : 1*40HQ

Packaging Details : Standard export packing carton

Delivery Time : 30 days

Payment Terms : 30% TT and balance before shipment

Supply Ability : 1*40HQ delivery time 35days

Contact Now

Wall Split Air Conditioner

Specification Sheet

Model OS-24HRFN1
Power supply Ph-V-Hz 220-240V~ 50Hz, 1Ph
Rated Cooling Capacity Btu/h 22000(7240~24640)
Cooling Power input W 171~2780
Cooling Current A 0.74~12.09
Rated Heating Capacity Btu/h 25000(4600~30000)
Heating Power input W 235~3140
Heating Current A 1.02~13.65
Seasonal Cooling Pdesignc kW 6.4
SEER W/W 6.1
Energy Efficiency Class A++
Heating(Average ) Pdesignh kW 5.2
SCOP W/W 4.0
Energy Efficiency Class A+
Tbiv -7
Heating(Warmer ) Pdesignh kW 7.1
SCOP W/W 4.8
Energy Efficiency Class A++
Tbiv 5
Tol -15
Moisture Removal L/h 2.3
Max. input consumption W 3100
Max. current A 14.5
Starting current A ----
Compressor Model DA150S1C-20FZ
Type Twin-rotary
Brand TOSHIBA
Capacity Btu/h 15286
Input W 1150
Rated current(RLA) A 9.7
Locked rotor Amp(LRA) A ----
Thermal protector KSD301
Thermal protector position EXTERNAL
Capacitor uF ---
Refrigerant oil/oil charge ml ESTER OIL VG74/500
Indoor fan motor Model WZDK58-38G
Brand Shibaura
Output W 58
Capacitor uF - -
Speed(Hi/Mi/Lo) r/min 1180 / 1100 / 900
Indoor coil a.Number of rows 2
b.Tube pitch(a)x row pitch(b) mm 21x13.37
c.Fin spacing mm 1.3
d.Fin type (code) Hydrophilic aluminium
e.Tube outside dia.and type mm Φ7, innergroove tube
f.Coil length x height x width mm 780x336x26.74
g.Number of circuits 4
Indoor air flow (Hi/Mi/Lo) m3/h 1150/1070/880
Indoor sound pressure level (Hi/Mi/Lo) dB(A) 49/43/36
Indoor sound power level (Hi) dB(A) 62
Indoor unit Dimension(W*D*H) mm 1045x235x315
Packing (W*D*H) mm 1135x395x315
Net/Gross weight Kg 12/15.2
Outdoor fan motor Model WZDK50-38G
Brand Shibaura
Output W 50
Capacitor uF - -
Speed r/min 800
Outdoor coil a.Number of rows 2
b.Tube pitch(a)x row pitch(b) mm 25.4x22
c.Fin spacing mm 1.4
d.Fin type (code) Hydrophilic aluminium
e.Tube outside dia.and type mm Φ9.52,innergroove tube
f.Coil length x height x width mm 766x660x44
g.Number of circuits 4
Outdoor air flow m3/h 2700
Outdoor sound pressure level dB(A) 60
Outdoor sound power level dB(A) 67
Outdoor unit Dimension(W*D*H) mm 845x320x700
Packing (W*D*H) mm 965x395x755
Net/Gross weight Kg 47 / 50
Refrigerant Type R410A
GWP 1975
Charged quantity Kg 1.95
Design pressure MPa 4.2/1.5
Refrigerant piping Liquid side/ Gas side mm(inch) Φ9.52/Φ15.9(3/8"/5/8")
Max. refrigerant pipe length m 30
Max. difference in level m 20
Connection wiring 2.5(Optional)
Plug type --
Thermostat type Remote Control
Operation temperature Indoor(cooling/ heating) 17~32/0~30
Outdoor(cooling/heating) -15~50/-15~30
Application area m2 32-53
Qty’per 20’ /40’ /40'HQ 69/140/160

Features:

Mute Operation

On the basis of low noise air duct system and quiet design, you can shut off the AC beep and display by pressing mute operation to create a super quiet environment.

Olyair O series wall mounted type split air conditioner

Selectable Control Modes

Apart from conventional remote control, Aurora split provide a variety of optional, including wired control, front desk control and central control.

Olyair O series wall mounted type split air conditioner

Optional functions: (If you need below add functions, please let me know)

1. Active carbon Filter

2. Photocatalyst Filter

3. Catechin Filter

4. Vitamin-enriching Filter

5. Nano Silver Filter

6. Air Ionizer

Our Services

1. Olyair Appliances insist high quality products reach every clients are safe without worry, so we will fully test each pc of product before leave factory.

2. As HVAC products we provide three year warranty for whole unit and compressor all use famous brand like toshiba, rechi etc.

and it lasts five years warranty also.

3. Each full container we will free to combine with 0.5%-1% spare parts based on each products request.

4. Olyair Provide OEM service which will in responsible for design the indoor and outdoor carton box. If you need have own panel design reqiuest just contact us we will ask engineer to give a strong idea for your long term development.

5. In general, when we receive your inquiry message, our information dept will send related colleage in the first time. So you will receive a reply within one hour. And if no any response, please contact our service team or visit our web to get some contact information.

6. We thank you for each client to read our any products in the web, so please let both of us value time, before send inquiry. please consider the products and it's specification you really need. Sometimes, some inquiry no any subject and don't confirm what they want, but just request to inform the payment terms and MOQ which made us difficult in reply an inquiry.

Packaging & Shipping

Wall Split Packing

Olyair O series wall mounted type split air conditioner

Window Packing Carton:

Olyair O series wall mounted type split air conditioner

Floor Standing Packing:

Olyair O series wall mounted type split air conditioner

Olyair O series wall mounted type split air conditioner

Olyair O series wall mounted type split air conditioner

Actual pictures of the panel:

Olyair O series wall mounted type split air conditioner

Company Information

Olyair O series wall mounted type split air conditioner

Olyair O series wall mounted type split air conditionerOlyair O series wall mounted type split air conditionerOlyair O series wall mounted type split air conditionerOlyair O series wall mounted type split air conditioner

FAQ

1. Why the heating of the air conditioner does not function?

Answer: Our remote control is designed to have both ‘cooling only’ mold and ‘cooling & heating’ mold. Users need to activate either the ‘cooling only’ mold or the ‘cooling & heating’ mold. If ‘cooling only’ mode is activated, the heating function of the air conditioner will not work, it will starting heating up the room temperature only when you turn it into ‘cooling & heating’ mold. The way of setting is demonstrated in detail in the user’s manual.

2. Why the air conditioner does not blow out hot air until several minutes after it is activated?

Answer: This is because when the heating mold just started, the temperature of evaporator is relatively low and the wind blow out would be cool. Therefore, there has designed a function of cool air protection, which will stop the indoor fan from working until the evaporator reach the set temperature. Thus, there will not be any wind blow out at the beginning.


3. Why the air conditioner does not work for the first 3 minutes, after it is restarted after a sudden power lost?


Answer: This is because our air conditioning has been set up with the power lost memory function (AUTO - RESTART), when suddenly power off and then immediately power on, the air conditioner will operate according to the same setting before the power off. Therefore, in order to prevent the impact of imbalance system to the compressor on its startup, the compressor will re-start operating 3 minutes delay. Thus, the condition will not either heat up or cool down the room temperature in these 3 minutes.

4. Why the capacity of new air condition seemed not strong enough to cool down the room temperature?


Answer: There could be various reasons:
1) The capacity is insufficient, professional will be necessary for checking.
2) Wrong mode of air conditioner is brought, as the choice of models has a direct relationship with the following conditions:
A. The area of the room.
B. The cooling load of the room. It is related to the heat leakage, which is affected by the thermal insulation of room wall, large glass window and no. of heating source such as high voltage home appliances. The heat leakage will also be affected in places such as dining room and living room.
To our experience, capacity of air conditioner = room area X cooling load, cooling load can be between 160 to 220, depend on the heat leakage. For example, if there are not any large voltage home appliances and the thermal insulation is ok, the cooling load of a single room can be estimated as 160, and 170 for a double room, 200 for a living room and 220 for a dining room. Commercial areas should be estimated according to real situations.

Welcome to contact our service team for your project on air conditioner business. We count to be your wise supplier!


Quality Olyair O series wall mounted type split air conditioner for sale

Olyair O series wall mounted type split air conditioner Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Olyair Electric Appliances Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)